3,131 research outputs found

    Post processing of differential images for direct extrasolar planet detection from the ground

    Get PDF
    The direct imaging from the ground of extrasolar planets has become today a major astronomical and biological focus. This kind of imaging requires simultaneously the use of a dedicated high performance Adaptive Optics [AO] system and a differential imaging camera in order to cancel out the flux coming from the star. In addition, the use of sophisticated post-processing techniques is mandatory to achieve the ultimate detection performance required. In the framework of the SPHERE project, we present here the development of a new technique, based on Maximum A Posteriori [MAP] approach, able to estimate parameters of a faint companion in the vicinity of a bright star, using the multi-wavelength images, the AO closed-loop data as well as some knowledge on non-common path and differential aberrations. Simulation results show a 10^-5 detectivity at 5sigma for angular separation around 15lambda/D with only two images.Comment: 12 pages, 6 figures, This paper will be published in the proceedings of the conference Advances in Adaptive Optics (SPIE 6272), part of SPIE's Astronomical Telescopes & Instrumentation, 24-31 May 2006, Orlando, F

    Focal plane wavefront sensor achromatization : The multireference self-coherent camera

    Full text link
    High contrast imaging and spectroscopy provide unique constraints for exoplanet formation models as well as for planetary atmosphere models. But this can be challenging because of the planet-to-star small angular separation and high flux ratio. Recently, optimized instruments like SPHERE and GPI were installed on 8m-class telescopes. These will probe young gazeous exoplanets at large separations (~1au) but, because of uncalibrated aberrations that induce speckles in the coronagraphic images, they are not able to detect older and fainter planets. There are always aberrations that are slowly evolving in time. They create quasi-static speckles that cannot be calibrated a posteriori with sufficient accuracy. An active correction of these speckles is thus needed to reach very high contrast levels (>1e7). This requires a focal plane wavefront sensor. Our team proposed the SCC, the performance of which was demonstrated in the laboratory. As for all focal plane wavefront sensors, these are sensitive to chromatism and we propose an upgrade that mitigates the chromatism effects. First, we recall the principle of the SCC and we explain its limitations in polychromatic light. Then, we present and numerically study two upgrades to mitigate chromatism effects: the optical path difference method and the multireference self-coherent camera. Finally, we present laboratory tests of the latter solution. We demonstrate in the laboratory that the MRSCC camera can be used as a focal plane wavefront sensor in polychromatic light using an 80 nm bandwidth at 640 nm. We reach a performance that is close to the chromatic limitations of our bench: contrast of 4.5e-8 between 5 and 17 lambda/D. The performance of the MRSCC is promising for future high-contrast imaging instruments that aim to actively minimize the speckle intensity so as to detect and spectrally characterize faint old or light gaseous planets.Comment: 14 pages, 20 figure

    Laboratory validation of the dual-zone phase mask coronagraph in broadband light at the high-contrast imaging THD-testbed

    Full text link
    Specific high contrast imaging instruments are mandatory to characterize circumstellar disks and exoplanets around nearby stars. Coronagraphs are commonly used in these facilities to reject the diffracted light of an observed star and enable the direct imaging and spectroscopy of its circumstellar environment. One important property of the coronagraph is to be able to work in broadband light. Among several proposed coronagraphs, the dual-zone phase mask coronagraph is a promising solution for starlight rejection in broadband light. In this paper, we perform the first validation of this concept in laboratory. First, we recall the principle of the dual-zone phase mask coronagraph. Then, we describe the high-contrast imaging THD testbed, the manufacturing of the components and the quality-control procedures. Finally, we study the sensitivity of our coronagraph to low-order aberrations (inner working angle and defocus) and estimate its contrast performance. Our experimental broadband light results are compared with numerical simulations to check agreement with the performance predictions. With the manufactured prototype and using a dark hole technique based on the self-coherent camera, we obtain contrast levels down to 21082\,10^{-8} between 5 and 17λ0/D\,\lambda_0/D in monochromatic light (640 nm). We also reach contrast levels of 41084\,10^{-8} between 7 and 17λ0/D\lambda_0/D in broadband (λ0=675\lambda_0=675 nm, Δλ=250\Delta\lambda=250 nm and Δλ/λ0=40\Delta\lambda / \lambda_0 = 40 %), which demonstrates the excellent chromatic performance of the dual-zone phase mask coronagraph. The performance reached by the dual-zone phase mask coronagraph is promising for future high-contrast imaging instruments that aim at detecting and spectrally characterizing old or light gaseous planets.Comment: 9 pages, 16 figure

    An aperture masking mode for the MICADO instrument

    Full text link
    MICADO is a near-IR camera for the Europea ELT, featuring an extended field (75" diameter) for imaging, and also spectrographic and high contrast imaging capabilities. It has been chosen by ESO as one of the two first-light instruments. Although it is ultimately aimed at being fed by the MCAO module called MAORY, MICADO will come with an internal SCAO system that will be complementary to it and will deliver a high performance on axis correction, suitable for coronagraphic and pupil masking applications. The basis of the pupil masking approach is to ensure the stability of the optical transfer function, even in the case of residual errors after AO correction (due to non common path errors and quasi-static aberrations). Preliminary designs of pupil masks are presented. Trade-offs and technical choices, especially regarding redundancy and pupil tracking, are explained.Comment: SPIE 2014 Proceeding -- Montrea

    Antireflective photonic structure for coherent nonlinear spectroscopy of single magnetic quantum dots

    Full text link
    This work presents epitaxial growth and optical spectroscopy of CdTe quantum dots (QDs) in (Cd,Zn,Mg)Te barriers placed on the top of (Cd,Zn,Mg)Te distributed Bragg reflector. The formed photonic mode in our half-cavity structure permits to enhance the local excitation intensity and extraction efficiency of the QD photoluminescence, while suppressing the reflectance within the spectral range covering the QD transitions. This allows to perform coherent, nonlinear, resonant spectroscopy of individual QDs. The coherence dynamics of a charged exciton is measured via four-wave mixing, with the estimated dephasing time T2=(210±40)T_2=(210\,\pm\,40) ps. The same structure contains QDs doped with single Mn2+^{2+} ions, as detected in photoluminescence spectra. Our work therefore paves the way toward investigating and controlling an exciton coherence coupled, via ss,pp-dd exchange interaction, with an individual spin of a magnetic dopant.Comment: 6 pages, 5 figure

    Monensin and forskolin inhibit the transcription rate of sucrase-isomaltase but not the stability of its mRNA in Caco-2 cells

    Get PDF
    AbstractTreatment of Caco-2 cells with forskolin (25 μM) or monensin (1 μM) has previously been shown to cause a marked decrease in the level of sucrase-isomaltase (SI) mRNA, without any effect on the expression of dipeptidylpeptidase IV (DPP-IV). In the present work, we report that there is no significant difference in the stability of SI mRNA between control and treated cells. On the other hand, we demonstrate a decrease in the transcription rate of SI mRNA which is sufficient to account for the decrease in the steady-state level of SI mRNA both in forskolin- and monensin-treated Caco-2 cells

    A probable giant planet imaged in the Beta Pictoris disk

    Full text link
    Since the discovery of its dusty disk in 1984, Beta Pictoris has become the prototype of young early-type planetary systems, and there are now various indications that a massive Jovian planet is orbiting the star at ~ 10 AU. However, no planets have been detected around this star so far. Our goal was to investigate the close environment of Beta Pic, searching for planetary companion(s). Deep adaptive-optics L'-band images of Beta Pic were recorded using the NaCo instrument at the Very Large Telescope. A faint point-like signal is detected at a projected distance of ~ 8 AU from the star, within the North-East side of the dust disk. Various tests were made to rule out with a good confidence level possible instrumental or atmospheric artifacts. The probability of a foreground or background contaminant is extremely low, based in addition on the analysis of previous deep Hubble Space Telescope images. The object L'=11.2 apparent magnitude would indicate a typical temperature of ~1500 K and a mass of ~ 8 Jovian masses. If confirmed, it could explain the main morphological and dynamical peculiarities of the Beta Pic system. The present detection is unique among A-stars by the proximity of the resolved planet to its parent star. Its closeness and location inside the Beta Pic disk suggest a formation process by core accretion or disk instabilities rather than a binary-like formation process.Comment: 5 pages, 3 figures, 1 table. A&A Letters, in pres
    corecore